We had a visitor from Sierra Leone who came by the fire house tonight. He was participating in a leadership conference at Plattsburgh State for African teenagers and heard of our project. We explained how the bio-sand filters worked and what we were doing to improve their operation. He was excited about the project and thought he would like to take the information back to the other teenagers and bring them back to see the project. He indicated they would be very useful as they drink water from just anywhere. He asked if we would send him the filter. We said we would send him the technology. We showed him each of the parts and he said he would be able to get everything.

This was live confirmation that our project would be useful.

I Found Out

I have realized that being in the personnel department is just like being a secretary!



                                                                                Alex

SUNDAY 11 MARCH 2012

A small group meet on Sunday afternoon to work on the Tantalus.

First the group collected water from the Little Ausable River from the Route 22 overpass. They threw a bucket down to the water attached to a 100ft cord and hauled water to fill two 5 gallon buckets. To ensure the bucket would not get pulled away with the current, the end was tied to the railing.  
Emma preparing to drop the bucket over
 
The Water Hauling Team

It's a long way down!
Bradley waiting for his turn

After hauling the water back to the fire station and filling the two biosand  filters, they set to work on adding a “Cup” device to the pipe inside the bucket. A hole needed to be drilled in the plastic cup to fit the “fitting” through. One of the leaders discovered the drill bit was in his tool bag BUT not the drill. The fire department did not have one. (They asked.) Liam put the plastic cup in the fire department vice and with a pare of adjustable pliers holding the drill bit, hand drilled the hole. 

 Liam drilling the hole by hand
Since this was a lengthy process to get through the plastic, the other members learned to use the Turbidity meter. First they had to gather samples:

Filling the sample bottle

Putting on the screw cap
Filling the testing jar

With help from the Matt (leader who has used one before) and a quick cursory read of the directions, we started testing the water. We opted to use the number 10 solution for the calibration. We tested the water that was collected from the Little Ausable and it has a turbidity of 24. The guide said we wanted below 0.3 to drink. We tested the water coming out of each filter. The Red filter (natural sand) has a reading of 3.4 and the Black filter (manufactured sand) has a reading of 0.31. We were ecstatic! Our filters were definitely starting to work.
Reading the turbidity meter results


By the time the water testing was done, Liam (with a very sore hand) had the hole drilled. We added it to the inside of the pipe in the bucket to generate more air pressure so regulate the flow in the Tantalus better. It helped build more air pressure but there was a constant drip instead of a shut off.
Plastic dish with fitting attached
A look from the inside
Bradley holding the whole assembly

Then came the 2 hours of watching the Tantalus work and making minor modifications. We moved the coils, cut cable ties (intentionally restricting the flow in places as well as holding loops together), and changed the height of the pipe inside the bucket. After about 40 minutes of watching, Madeline and Bradley noticed that the problem seemed to be in the two-coil loop. They suspected if the coil was just one loop, the Tantalus would operate effectively. We were waiting for one leader to return with dinner before we cut the plastic tubing, so the other leader held the plastic piping in position. (It was too long with only one loop and kept wanting to recoil.) Matt actually had a short piece of plastic tubing that Liam bent into a loop and tied with cable ties. It worked! (Sort of a Eureka moment!) We watched it for about an hour to make sure it would constantly work.

Grace spent most to the time working on the guidelines for making the turbidity meter work. We learned you can only calibrate the system a couple of times and then it won't let you for a while. We learned that the same sample can give different reading so a procedure would need to be developed.


Members Present: Bradley N., Liam S., Grace S., Emma S., Madeline L., plus two leaders and one parent